Page 36 - Portfolio-Dhananjay Bhattacharya
P. 36
CORES FOR VERTICAL
ACCESS Despite given repre-
sentations, the site
of Viva City is
contoured with lower
TOWER 1 portion of the site
being low by approx
2m. So the basement
parking had to be
TOWER 2
designed on two
seperate levels.
BASEMENT PARKING
VEHICLE RAMPS
CasaGrand
Viva City -
Conceptuals
The Basement Level have a main
basement which is 4 m below
ground level and a smaller area
The G+10 storey residential towers have been given 2m below the ground which acts
strategically placed access points for vertical circulation as a stilt parking under a portion
(lifts, fire lifts, staircases) on all the floors in radius not of Tower 1 with attached road at
exceeding 35 m from any point on a floor for fire break- the lower portion of the
outs, etc. as per the bye-laws. contoured site.